A generalized system of tissue-mimicking materials for computed tomography and magnetic resonance imaging
Kamal Singhrao1, Jie Fu1, Yu Gao2
1Department of Radiation Oncology, University of California Los Angeles, Los Angeles, CA 90095, United States of America.
Abstract:
The advent of technologies such as magnetic resonance imaging (MRI)-guided radiation therapy has led to the need for phantom materials that are capable of producing tissue-like contrast on both MRI and computed tomography (CT) imaging modalities. The purpose of this work is to develop a system of easily made and formed materials with adjustable T1 and T2 relaxation times, and x-ray attenuation properties, for mimicking soft tissue and bone with both MRI and CT imaging modalities. The effects on T1/T2 relaxation times and CT numbers were quantified for a range of gadolinium contrast (0-25 μmol g-1), agarose (0%-8% w/w), glass microspheres (0%-10% w/w) and CaCO3 (0%-50% w/w) concentrations in a carrageenan-based gel. 105 gel samples were prepared with the additives, carrageenan and water. Samples were imaged in a 3D-printed holding structure to find the attainable range of T1/T2 relaxation time and CT number combinations. T1 and T2 relaxation time maps were generated using voxel-wise inversion-recovery and spin-echo techniques, respectively. A multivariate linear regression model was generated to allow the materials system to be generalized to semi-arbitrary T1/T2 relaxation times and CT numbers. Nine diverse tissue types were mimicked for fit model validation. The achievable T1/T2 relaxation times and CT numbers for the additive concentrations tested in this study spanned from 82 to 2180 ms, 12 to 475 ms, and -117 to +914 Hounsfield units (HU), respectively. The mean absolute error between the fit model predicted and measured T1/T2 relaxation times and CT numbers for the nine tested tissue types was 113 ± 64 ms, 16 ± 26 ms and 11 ± 14 HU, respectively. In conclusion, we have created a system of materials capable of producing tissue-like contrast for 3.0 T MRI and CT imaging modalities.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging