Second and third trimester fetal ultrasound population screening for risks of preterm birth and small-size and

Jan S Erkamp1,2, Ellis Voerman1,2, Eric A P Steegers3

  • 1The Generation R Study Group, Erasmus MC, University Medical Center Rotterdam, P.O. Box 2040, 3000, CA, Rotterdam, the Netherlands.

BMC Medicine
|April 8, 2020
PubMed

Insights

Third trimester ultrasound screening, combined with maternal factors, best identifies risks for preterm birth, small for gestational age (SGA), and large for gestational age (LGA) babies. This approach significantly improves detection rates compared to second trimester screening alone.

Area of Science:

  • Maternal-fetal medicine
  • Diagnostic imaging in obstetrics
  • Perinatal health outcomes

Background:

  • Preterm birth, small for gestational age (SGA), and large for gestational age (LGA) are significant risk factors for neonatal and long-term health issues.
  • Optimal timing for ultrasound screening to identify fetuses at risk for these adverse outcomes remains unclear.
  • This study investigates the effectiveness of second and third trimester ultrasounds, alone and combined with maternal characteristics, for risk prediction.

Purpose of the Study:

  • To determine the optimal period for ultrasound screening to detect fetuses at risk of preterm birth, SGA, or LGA.
  • To evaluate the combined effectiveness of maternal characteristics and ultrasound measures (fetal weight, placental flow) in screening for adverse birth outcomes.
  • To compare the performance of single versus combined trimester screening strategies.

Main Methods:

  • A prospective, population-based cohort study involving 7677 pregnant women.
  • Measurement of second and third trimester estimated fetal weight (EFW) and placental flow indices (uterine artery pulsatility, umbilical artery resistance).
  • Screening performance assessed using receiver operating characteristic (ROC) curves and area under the curve (AUC), with sensitivity and specificity analysis.

Main Results:

  • Maternal characteristics combined with second trimester EFW showed moderate screening performance.
  • Adding third trimester EFW to maternal characteristics significantly improved AUC for preterm birth (0.64), SGA (0.79), and LGA (0.76).
  • Incorporating third trimester placental measures further enhanced screening for preterm birth (AUC 0.72) and SGA (AUC 0.83), but combining second and third trimester data did not outperform third trimester results alone.

Conclusions:

  • Combining third trimester ultrasound findings (fetal and placental measures) with maternal characteristics offers the best screening performance for preterm birth, SGA, and LGA risks.
  • Third trimester screening demonstrates a potential to double the detection rate of fetuses at risk for common adverse birth outcomes compared to second trimester screening.
Abstract

Related Concept Videos