Related Experiment Video
Updated: Dec 24, 2025

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
Subsidence Following Revision Total Hip Arthroplasty Using Modular and Monolithic Components
Andrew J Clair1, Jonathan A Gabor1, Karan S Patel1
1Department of Orthopaedic Surgery, NYU Langone Medical Center, NYU Langone Orthopedic Hospital, New York, NY.
Monoblock tapered, fluted, titanium (TFT) stems show less subsidence in revision total hip arthroplasty (rTHA) compared to modular stems. This finding is crucial for orthopedic surgeons managing rTHA to prevent complications like aseptic loosening.
Area of Science:
- Orthopedic Surgery
- Biomaterials Engineering
- Radiology
Background:
- The optimal femoral component for revision total hip arthroplasty (rTHA) is debated.
- Tapered, fluted, titanium (TFT) stems are frequently used in rTHA, with both modular and monoblock designs available.
- Femoral stem subsidence is a concern, potentially leading to aseptic loosening, instability, and leg length discrepancy.
Purpose of the Study:
- To compare the stem subsidence between modular and monoblock TFT stems in rTHA.
- To evaluate the incidence of significant subsidence (>5 mm) in both stem types.
Main Methods:
- Retrospective review of electronic medical records for rTHAs using modular or monoblock TFT stems from January 2013 to March 2018.
- Data collection included patient demographics, surgical indications, Paprosky classification, and stem subsidence at follow-up (3 months to 3 years).
- Statistical analysis employed two-sample t-tests and chi-squared tests.
Main Results:
- A total of 186 patients (106 modular, 80 monoblock) were analyzed.
- Modular stems exhibited significantly greater subsidence (3.9 ± 2.6 mm) than monoblock stems (2.3 ± 2.5 mm) (P < .001).
- A higher proportion of modular stems showed >5 mm subsidence (29.2%) compared to monoblock stems (11.3%) (P < .001).
Conclusions:
- Monoblock TFT stems demonstrated a lower incidence of postoperative subsidence compared to modular TFT stems.
- The findings suggest that monoblock TFT stems may offer an advantage in reducing subsidence-related complications in rTHA.
- Surgeons should consider the risk of subsidence when choosing between modular and monoblock TFT stems for rTHA.
More Related Videos
09:31Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022