Can Ultrasound Measures of Muscle and Adipose Tissue Thickness Predict Body Composition of Premature Infants in the Neonatal Intensive Care Unit?
Related Experiment Video
Updated: Dec 24, 2025

Author Spotlight: Assessing Surgical Frailty with Point-of-Care Ultrasound of Quadriceps Muscles
Published on: July 26, 2024
Emily Nagel1, Marie Hickey2, Levi Teigen3
1Department of Food Science and Nutrition, University of Minnesota-Twin Cities, Minneapolis, Minnesota, USA.
Insights
Ultrasound measurements of infant adipose tissue thickness did not accurately predict whole-body composition. Further research is needed to find reliable methods for monitoring premature infant growth and preventing future health issues.
Area of Science:
- Neonatalogy
- Pediatric Nutrition
- Medical Imaging
Background:
- Premature infants face risks for metabolic and neurodevelopmental issues due to altered growth.
- Monitoring body composition (fat mass, fat-free mass) is crucial for preventing obesity and promoting optimal development.
- Ultrasound (US) is explored as a tool to assess body composition in neonates.
Purpose of the Study:
- To evaluate the effectiveness of ultrasound (US) measurements of muscle and adipose tissue thickness in predicting whole-body composition in premature infants.
- To determine if US can serve as a surrogate for accurate body composition assessment in this vulnerable population.
Main Methods:
- A prospective, observational study included 63 healthy premature infants.
- Measurements included anthropometry, air displacement plethysmography, and US of abdomen, biceps, and quadriceps.
- Stepwise linear regression analysis assessed the relationship between US measurements and body composition.
Main Results:
- Biceps adipose and summed adipose tissue thickness were weak predictors of percent body fat (%BF), with low R-squared values (0.17, 0.16).
- Ultrasound measurements of muscle thickness did not predict whole-body fat-free mass (FFM).
- Prediction models demonstrated high error, indicating poor accuracy.
Conclusions:
- Current ultrasound measurements of muscle and adipose tissue thickness at examined sites are insufficient for assessing whole-body composition in preterm infants.
- Alternative measurement sites or methods may be necessary to improve predictive accuracy for neonatal body composition.
Background:
Premature infants are at risk for adverse metabolic and neurodevelopmental outcomes due to growth alterations in early infancy. Monitoring body composition by tracking gains in fat mass (FM) and fat-free mass (FFM) may assist clinicians in preventing obesity and metabolic disease while promoting optimal growth and development. A prospective, observational study was conducted to determine the ability of ultrasound (US) measurements of muscle and adipose tissue thickness to predict whole-body composition (FFM, FM, percent body fat [%BF]).
Methods:
Sixty-three healthy premature infants were recruited from the University of Minnesota's Neonatal Intensive Care Unit. Anthropometric measurements, air displacement plethysmography, and US measurements of abdomen, biceps, and quadriceps muscle and of adipose tissue thickness were conducted when infants were medically stable. The relationship between US measurements and body composition was assessed using stepwise linear regression analysis.
Results:
In linear regression analyses, biceps adipose and the sum of adipose thickness measurements were significant predictors of %BF, but prediction models had low R2 (0.17 and 0.16, respectively) and high root-mean-square error. US measurements of muscle thickness were not predictive of whole-body FFM.
Conclusion:
US measurements of muscle and adipose tissue thickness at the examined sites are not adequate surrogates for whole-body composition in preterm infants. Exploration of alternate measurement sites may improve predictive ability.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies II: Ultrasonography