Related Experiment Video
Updated: Dec 24, 2025

Author Spotlight: Non-Invasive Imaging of Complex Bio-Structures Using Polarization-Sensitive Two-Photon Microscopy
Published on: September 8, 2023
Polarization-Based Sensing with a Self-Referenced Sample
Joseph R Lakowicz1, Ignacy Gryczynski1, Zygmunt Gryczynski1
1Department of Biochemistry and Molecular Biology, Center for Fluorescence Spectroscopy, University of Maryland School of Medicine, 725 West Lombard Street, Baltimore, Maryland 21201 (J.R.L., I.G., Z.G., L.T., J.D.D.); and Medical Biotechnology Center and Department of Chemical and Biochemical Engineering, University of Maryland Biotechnology Institute, 725 West Lombard Street, Baltimore, Maryland 21201 (G.R.).
Abstract:
We describe a new method of fluorescence sensing based on fluorescence polarization. The sensor consists of two compartments, both of which contain the sensing fluorophore. One side of the sensor contains a constant concentration of analyte, and the other contains the unknown concentration. Emission from both sides is observed through polarizers, with the polarization from the sample being rotated 90° from that of the reference. Changes in the fluorescence intensity of the sample result in changes in the measured polarization for the combined emission. We show that this approach can be used to measure glucose and calcium using fluorophores which show analyte-dependent intensity changes, and no change in the spectral shape. Only a single fluorophore is required, this being the sensing fluorophore in both sides of the sensor. We also show that polarization sensing of glucose and calcium can be performed with visual detection of the polarization. In this case the only electronic component is the light source. These simple schemes can be used with a variety of analytes. The only requirement is a change in fluorescence intensity in response to the analyte.
More Related Videos
14:18Automation of Mode Locking in a Nonlinear Polarization Rotation Fiber Laser through Output Polarization Measurements
Published on: February 28, 2016
07:56A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference
Published on: September 5, 2019
Related Concept Videos
Dielectric Polarization in a Capacitor
Potential Due to a Polarized Object
Measuring Reaction Rates
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
Group Polarization