Related Experiment Video
Updated: Dec 24, 2025

Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Ultrasound-Guided Percutaneous Balloon Aortic Valvuloplasty for Aortic Stenosis
Yedan Li1, Kunjing Pang1, Yao Liu2
1Department of Echocardiography, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China.
Abstract:
Percutaneous balloon aortic valvuloplasty (PBAV), which is used to treat symptomatic aortic stenosis, requires ionizing radiation and contrast agent for imaging guidance. The aim of the study is to evaluate the feasibility and effectiveness of ultrasound-guided PBAV in patients with aortic stenosis. This case series included 30 patients (14 males; mean age, 61.5 ± 4.5 years) with moderate/severe aortic stenosis treated with ultrasound-guided PBAV at the Ultrasound Department, Fuwai Hospital, Beijing, China, between January 2016 and July 2019. Cardiac function (New York Heart Association grade) was assessed before PBAV and 1 month after the procedure. Aortic peak jet velocity, aortic valve orifice area (AVA), mean transvalvular pressure gradient (MTPG), left ventricular end-diastolic diameter (LVDD), left ventricular ejection fraction (LVEF), and left ventricular end-systolic diameter (LVESD) were determined before and immediately after PBAV using Doppler echocardiography. Preprocedural cardiac function was grade I in 3 cases, grade II in 9 cases, grade III in 10 cases, and grade IV in 8 cases. Postprocedural cardiac function was grade I in 22 cases, grade II in 4 cases, and grade III in 4 cases, suggesting that cardiac function was improved by PBAV. Ultrasound-guided PBAV resulted in significant improvements (P < 0.05) in aortic peak jet velocity (3.68 ± 0.811 m/s vs. 4.79 ± 0.63 m/s), MTPG (33.77 ± 13.85 mmHg vs. 54.54 ± 13.81 mmHg), AVA (1.96 ± 0.25 cm2 vs. 0.98 ± 0.12 cm2), LVEDD (51.90 ± 3.21 mm vs. 65.60 ± 6.81 mm), LVEF (63.46 ± 11.29% vs. 56.31 ± 11.04%), and LVESD (35.50 2.62 mm vs. 45.20 ± 2.42 mm). Ultrasound-guided PBAV is feasible and achieves good short-term effects in patients with aortic stenosis.
More Related Videos
06:59Catheter-based Endovascular Angioplasty for Fibrosing Mediastinitis-associated Pulmonary Vein Stenosis
Published on: August 26, 2025
06:51Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research
Published on: October 20, 2023
Related Concept Videos
Mitral Stenosis III: Medical Management
Peripheral Artery Disease III: Interprofessional Care