Causes of Preanalytical Interferences on Laboratory Immunoassays - A Critical Review
Beatrice Caruso1, Chiara Bovo2, Gian Cesare Guidi3
1Medical Laboratory Direction, "Carlo Poma" Hospital, Mantua, Italy.
Abstract:
The immunoassays methods need avoiding interferences that can influence result interpretation. Main sources of interference arise from either patient status, preparation and physiology or laboratory process and procedures. The aim of this non-systematic critical review is to highlight the preanalytical interferences on laboratory immunoassays. Blood hormone profile changes according with age and depending on sex: these are important variables, mainly in newborn, during both sexual maturation and childbearing. Gonadotropins FSH and LH show a sharp increase with age in females, whereas in males LH appears rather stable. With age both males and females show progressive decay of the hormone profile. Stress causes variations, as it influences GH, prolactin, Cortisol and the total/free ratio of thyroid hormone. Diurnal variations, day of cycle, influence by estrogens on thyroid hormone are relevant for result variability. Paraproteins and autoantibodies can interfere in some assays particularly drug, vitamin D and thyroid hormone. As regards the variables due to sample matrix, and to evacuated tubes components, some additives and anticoagulants have been reported to influence specific assays, e.g. thyroid hormone. Hemolysis, lipemia and bilirubin cause interferences on specific techniques/tests, e.g. ferritin, TSH, Vitamin B12, progesterone and folic acid. Nicotine and cocaine addictions interfere with some hormones. Thus, laboratory professionals should be aware of preanalytical problems particularly important when dealing with the immunoassays, by taking appropriate actions to avoid any relevant interferences.
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Immunoprecipitation
Chromatin Immunoprecipitation
Chromatin immunoprecipitation, also known as ChIP, is used to study protein-DNA or...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
Overview Of Cell Separation And Isolation