Related Experiment Video
Updated: Dec 24, 2025

Automated, High-resolution Mobile Collection System for the Nitrogen Isotopic Analysis of NOx
Published on: December 20, 2016
Validated Reversed-Phase Ion-Interaction High-Performance Liquid Chromatography for Quantitation of Nitrate Content
Chaowalit Monton1, Jirapornchai Suksaeree2, Chitradee Luprasong3
1Drug and Herbal Product Research and Development Center, College of Pharmacy, Rangsit University, Pathum Thani 12000, Thailand.
Abstract:
This work sought to validate the reversed-phase ion-interaction high-performance liquid chromatography for quantifying the nitrate content in the extract and raw material of Clausena anisata (Willd.) Hook. f. ex Benth. leaves. Three extraction methods (i.e., decoction, infusion, and ultrasound-assisted extraction) were investigated and compared. Furthermore, the effect of the solid-to-solvent ratio and defatting was also evaluated. The validation result showed that the high-performance liquid chromatographic method had a linear response (R 2 = 0.9999) in the range of 1-50 μg/mL. The limit of detection and limit of quantitation were 0.25 μg/mL and 0.75 μg/mL, respectively. In addition, the method was specific, precise, and accurate. So the validated method was suitable for determination of the nitrate content in C. anisata leaves. Infusion of a nondefatted sample using a solid-to-solvent ratio of 1 : 10 gave the highest nitrate content in the raw material, 0.251 ± 0.003%. In case of a defatted sample, decoction provided the highest nitrate content, 0.309 ± 0.001%. Increasing the solid-to-solvent ratio and defatting had a huge effect on the nitrate content of C. anisata leaves extracted from decoction. To the best of our knowledge, this is the first report that used the reversed-phase ion-interaction high-performance liquid chromatography for quantifying the nitrate content in C. anisata leaves. Furthermore, the authors suggested that nitrate could be used as a standard marker for quality control of C. anisata leaves' extract and raw material.
More Related Videos
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
07:38A General Method for Detecting Nitrosamide Formation in the In Vitro Metabolism of Nitrosamines by Cytochrome P450s
Published on: September 25, 2017
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process