Related Experiment Video
Updated: Dec 24, 2025

Home-Based Prescribed Pulmonary Exercise in Patients with Stable Chronic Obstructive Pulmonary Disease
Published on: August 24, 2019
Effect of portable non-invasive ventilation on exercise tolerance in COPD: One size does not fit all
Nikolaos Chynkiamis1, Matthew Armstrong1, Emily Hume1
1Department of Sport, Exercise and Rehabilitation, Northumbria University Newcastle, Newcastle Upon-Tyne NE1 8ST, UK.
Abstract:
In a cross-over RCT, portable NIV (pNIV) reduced dynamic hyperinflation (DH) compared to pursed lip breathing (PLB) during recovery from intermittent exercise in COPD, but not consistently in all subjects. In this post-hoc analysis, DH response was defined as a reduction ≥4.5 % of predicted resting inspiratory capacity with pNIV compared to PLB. At exercise iso-time (where work completed was consistent between pNIV and PLB), 8/24 patients were DH non-responders (DH: 240 ± 40 mL, p = 0.001 greater using pNIV). 16/24 were DH responders (DH: 220 ± 50 mL, p = 0.001 lower using pNIV). Compared to DH responders, DH non-responders exhibited greater resting DH (RV/TLC: 65 ± 4% versus 56 ± 2%; p = 0.028) and did not improve exercise tolerance (pNIV: 30.9 ± 3.4 versus PLB: 29.9 ± 3.3 min; p = 0.603). DH responders increased exercise tolerance (pNIV: 34.9 ± 2.4 versus PLB: 27.1 ± 2.3 min; p = 0.001). Resting RV/TLC% was negatively associated with the magnitude of DH when using pNIV compared to PLB (r=-0.42; p = 0.043). Patients with profound DH were less likely to improve exercise tolerance with pNIV. Further studies using auto-adjusted ventilators are warranted.
More Related Videos
08:44Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
COPD: Management Using Bronchodilators and Corticosteroids
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Chronic Obstructive Pulmonary Disease-I: Introduction