Tomography system for two-dimensional observation of fluctuation in magnetized plasma
K Yamasaki1, A Fujisawa1, Y Nagashima1
1Research Institute for Applied Mechanics, Kyushu University, Kasuga 816-8580, Japan.
Abstract:
A tomography system is developed for observing local fluctuations, pursuing higher spatial resolution, over the entire plasma of a linear cylindrical plasma. The system is equipped with totally 126 lines-of-sight that are distributed equally to six sets of light guide arrays placed around the plasma. The system has succeeded in measuring the two-dimensional structure of plasma emission and resolving coherent fluctuation structures, with spatial resolution comparable to the ion Larmor radius.