Related Experiment Video
Updated: Dec 24, 2025

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
ECG markers of local but not global increase in dispersion of ventricular repolarization (simulation study)
Natalia V Arteyeva1, Jan E Azarov2
1Department of Cardiac Physiology, Institute of Physiology, Komi Science Center, Ural Branch, Russian Academy of Sciences, 50, Pervomayskaya st., Syktyvkar 167982, Russia.
Background:
An increase in local dispersion of repolarization (DOR) may contribute more to arrhythmogenesis as compared to changes of global DOR. The aim of this simulation study was to find ECG markers of local increase in DOR in conditions where global DOR remains normal.
Methods:
In the framework of van Oosterom and Oostendorp ECGSIM model, the local DOR was increased in 10 different ventricular locations by (1) action potential duration (APD) shortening/lengthening both on epi- and endocardium, (2) epicardial APD shortening, and (3) endocardial APD shortening. The simulation cases where the increase in local DOR was accompanied by increase in global DOR were excluded from consideration. T-wave parameters were analyzed in the simulated precordial and anatomically ordered limb leads.
Results:
The increase in local DOR resulted in increased lead-to‑lead differences in Tpeak and Tend instants in 28 out of 32 simulated scenarios, and in an increased dispersion of Tpeak-Tend interval throughout 12 standard leads in 8 out of 32 simulated scenarios. In all simulations, the global DOR measured as a difference between earliest and latest repolarization times and standard APD deviation was the same.
Conclusions:
The local increase in DOR was expressed in increased lead-to‑lead differences in Tpeak and Tend instants between adjacent anatomically ordered standard leads (aVL, I, aVR(-), II, aVF, III, and V1-V6), even if global DOR, Tpeak-Tend interval and Tpeak-Tend dispersion were within a normal range.
More Related Videos
09:52Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts
Published on: November 7, 2019
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Electrophysiology of Normal Cardiac Rhythm
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias