WO3-Based Gas Sensors: Identifying Inherent Qualities and Understanding the Sensing Mechanism
Anna Staerz1, Simona Somacescu2, Mauro Epifani3
1Institute for Physical and Theoretical Chemistry, Eberhard Karls University of Tuebingen, 72076 Tuebingen, Germany.
Abstract:
Semiconducting metal oxide-based gas sensors are an attractive option for a wide array of applications. In particular, sensors based on WO3 are promising for applications varying from indoor air quality to breath analysis. There is a great breadth of literature which examines how the sensing characteristics of WO3 can be tuned via changes in, for example, morphology or surface additives. Because of variations in measurement conditions, however, it is difficult to identify inherent qualities of WO3 from these reports. Here, the sensing behavior of five different WO3 samples is examined. The samples show good complementarity to SnO2 (the most commonly used material)-based sensors. A surprising homogeneity, despite variation in morphology and preparation method, is found. Using operando diffuse reflectance infrared Fourier transform spectroscopy, it is found that the oxygen vacancies are the dominant reaction partner of WO3 with the analyte gas. This surface chemistry is offered as an explanation for the homogeneity of WO3-based sensors.
More Related Videos
10:42Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Potentiometry: Membrane Electrodes