Related Experiment Video
Updated: Dec 24, 2025

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
Institutional Variability in Patient Radiation Doses ≥5 Gy During Percutaneous Coronary Intervention
Ryan D Madder1, Simon R Dixon2, Milan Seth3
1Frederik Meijer Heart & Vascular Institute, Spectrum Health, Grand Rapids, Michigan.
Objectives:
The aim of this study was to evaluate institutional variability in high radiation doses during percutaneous coronary intervention (PCI).
Background:
It is unknown whether radiation safety practices are optimally applied across institutions performing PCI.
Methods:
Using data from a large statewide registry, PCI discharges between July 1, 2016, and March 31, 2018, with a procedural air kerma (AK) recorded were analyzed. PCI procedures were grouped by the performing hospital, and institutional frequency of procedural AK ≥5 Gy was calculated. Fitted hierarchical Bayesian modeling was performed to identify variables independently associated with an AK ≥5 Gy. The performing hospital was included as a random effect in the hierarchical model.
Results:
Among 36,201 PCI procedures at 28 hospitals, procedural AK was ≥5 Gy in 1,477 cases (4.1%), ≥10 Gy in 185 (0.5%), and ≥15 Gy in 105 (0.3%). The institutional frequency of procedural AK ≥5 Gy ranged from 0.0% to 10.9%. Bayesian modeling identified body mass index, dyslipidemia, diabetes, prior coronary bypass surgery, use of mechanical circulatory support, and the performing hospital as independent predictors of an AK ≥5 Gy. The median odds ratio for the performing hospital, representing an estimate of the contribution of interhospital variability in determining the odds of having a procedural AK ≥5 Gy, was 3.08 (95% confidence interval: 3.01 to 3.16).
Conclusions:
Wide variability exists in the institutional frequency of procedural AK ≥5 Gy during PCI. After accounting for patient characteristics and procedural variables, the performing hospital appears to be a major factor in determining patient radiation dose in contemporary PCI.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
11:38Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Related Concept Videos
Dosage Regimen: Individualization
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization IV: Nursing Management
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...