Related Experiment Video
Updated: Dec 24, 2025

Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
Published on: January 24, 2018
Retrograde nailing, trabecular metal implant and use of bone marrow aspirate concentrate after failed ankle joint
Mads Sundet1, Elena Johnsen2, Kari Helene Eikvar3
1Consultant Foot and Ankle Surgeon, Diakonhjemmet Hospital, Oslo, Norway.
Background:
Ankle fusion after removal of alloplasty is known to be a procedure with a high potential for non-unions and poor function, especially tibio-talo-calcaneal fusion. We wanted to review our results after using a novel method for the procedure, combining retrograde nailing with a trabecular metal implant and bone marrow aspirate concentration applied in an ostoconductive pad in addition to autologous bone grafting.
Materials And Methods:
Retrospective review of a patient series, with some prospectively registered data. 31 ankles in 30 patients were operated from January 2016 to February 2019.
Results:
There were two non-unions (6.5%), and one delayed union, none of these were reoperated. The mean postoperative Manchester-Oxford Foot and Ankle Questionnaire score (MOxFQ) was 33.6 points. 9 patients scored an average MOxFQ at 72.9 immediately before surgery, while at follow-up this had decreased to 36.2, an improvement of 36.7 points (95% CI 18.3-54.9). There were 1 minor infection and 5 possible nerve injuries. One patient had the leg amputated 1 year after the surgery due to a non-related necrotizing fasciitis.
Conclusion:
We present reasonably good short to medium term patient satisfaction and fusion rates with this novel combination of techniques.