Tidal Breathing Parameters Measured by Structured Light Plethysmography in Newborns: Is It Feasible in Neonatal
Evrim Alyamac Dizdar1, Davut Bozkaya1, Fatma Nur Sari1
1Neonatal Intensive Care Unit, University of Health Sciences, Ankara City Hospital, Çankaya, Ankara, Turkey.
Objective:
Structured light plethysmography (SLP) is a novel and noncontact respiratory assessment technique. It provides tidal breathing measurement in patients difficult to cooperate. In this study, we aimed to determine data for tidal breathing parameters measured by SLP in newborns.
Study Design:
Infants between 2 and 5 days of life without having any respiratory symptoms were eligible for this observational study. In total, 5 minutes of tidal breathing was recorded using SLP (Thora-3Di, PneumaCare Ltd, Cambridge, U.K.) in each infant. Various tidal breathing parameters including timing indices, flow-based parameters, and regional parameters were obtained from SLP data.
Results:
A total of 57 infants underwent measurements in the study. Evaluable recordings from 42 term and 11 late preterm infants were analyzed. Median gestational age and birthweight of the infants were 38 (37-39) weeks and 3,195 (2,790-3,585) g, respectively. In terms of flow-based parameters, "tidal inspiratory flow at 50% of inspiratory volume divided by tidal expiratory flow at 50% of expiratory volume" was 1.29 (1.13-1.53). Relative contribution of the thorax to each breath in percentage was measured as 38.67 (28.21-43.60). Median values of left-right hemithoracic asynchrony and thoraco-abdominal asynchrony were 6.92 (5.35-9.04) and 17.96 (12.98-36.44) degrees in the study population, respectively. There were no differences in tidal breathing parameters except "hemithoracic asynchrony" between term and late preterm infants. Hemithoracic asynchrony was significantly lower in term neonates than late preterms.
Conclusion:
SLP was found to be feasible to obtain measures of tidal breathing parameters in newborns and it could be performed successfully even in the first days of life.
More Related Videos
08:30Intraperitoneal Glucose Tolerance Test, Measurement of Lung Function, and Fixation of the Lung to Study the Impact of Obesity and Impaired Metabolism on Pulmonary Outcomes
Published on: March 15, 2018
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: