Related Experiment Video
Updated: Dec 24, 2025

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Correlation between Vista Cam, ICDAS-II, X-ray bitewings and cavity extent after lesion excavation: an in-vivo pilot
Marta Mazur1, Maciej Jedlinski2, Iole Vozza3
1Department of Oral and Maxillofacial Sciences, Sapienza University, Rome, Italy - marta.mazur@uniroma1.it.
Background:
To correlate fluorescence-based camera (FC), visual inspection (ICDAS-II) and radiographic examination X-rays bitewings (BW) to the extent of caries after excavation.
Methods:
The occlusal sites of 20 permanent first and second molars in 14 young adolescents (12±2 years old) were examined at 1st Observation Unit of Department of Oral and Maxillofacial Sciences, "Sapienza" University of Rome. All the enrolled patients were asked to provide with X-rays bitewing of the studied teeth. The assessment of ICDAS-II and FC was performed by a trained operator. Then a second blind operator removed the carious lesion and evaluated the cavity extent (depth, width, length) after caries removal with a calibrated probe. To correlate FC measurements with bitewing sensitivity, 10 dentists evaluated the presence/absence of caries on the X-rays.
Results:
All the occlusal sites assessed by fluorescence camera, ranged from 1.7 to 2, indicating in all cases deep enamel lesions with possible extent to dentine with a mean of 1.7±0. In accordance, visual inspection by ICDAS-II showed scores of 3 and 4. By contrast, the radiographic documentation, i.e. bitewing X-rays, was evaluated in only 6 cases as presence of caries. The extent of the cavities was determined by three consecutive measurements: depth, width and length, with a mean of 3.5+1.73, 2.8+1.07 and 3.2+1.64 mm respectively. These results confirmed the agreement between FC and ICDAS-II for diagnosis of cavities with extent to enamel and dentine, while showed the low sensitivity of bitewings X-rays, in accordance with the existing evidence in Literature. Moreover, the results of this study for the first time provide information about the cavity extent after caries removal for the occlusal sites with ICDAS-II 3 and 4 scores and FC≥1.7.
Conclusions:
X-rays evaluation showed diagnostic accuracy in 6% of the sample. VistaCam measurement of 1.7 was correlated to a cavity with 3.5, 2.8 and 3.2 mm of depth, width and length.
More Related Videos
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

