Clinical evaluation of a novel press-fit acetabular cup using "Ein-Bild-Roentgen-Analysis" (EBRA): A positive
B A Ishaque1, J Wieczorek1, C A Fonseca Ulloa2
1Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstrasse 33, 35392, Giessen, Germany.
Introduction:
Demographic change and demand for high quality of life lead to increasing implantation numbers. Aim of this study was to compare the Plasmafit® cup to Allofit® and Plasmacup®.
Methods:
The study included 174 patients who had received 33 Plasmacup®, 68 Allofit® and 73 Plasmafit® cup implants. These were reviewed postoperatively, after 6 months control and after 12 months.
Results:
No significant progressive migration could be discovered in any of the cup systems. At each follow-up the cups showed nearly constant values.
Conclusions:
All examined acetabular cups showed excellent migration behavior within the first 12 postoperative months.