Related Experiment Video
Updated: Dec 24, 2025

Ultrasound Cyclo Plasty in Eyes with Glaucoma
Published on: January 26, 2018
Surgical Outcomes of a Second Ahmed Glaucoma Valve Implantation in Asian Eyes with Refractory Glaucoma
Sze Chuan Ong1, Maria Cecilia Aquino2, Paul Chew2
1Yong Loo Lin School of Medicine, National University of Singapore, 117597, Singapore.
Results:
The cumulative failure rates were 9.5%, 20.0%, 32.5%, and 46.0% at six months, one year, two years, and three years of follow-up. At final follow-up, complete success and qualified success rates were 23.8% and 33.3%, respectively; mean IOP and number of medications decreased by 5.6 mmHg (23.9%) and 1.7 mmHg (54.8%), respectively, from preoperative baseline (P < 0.01). More common postoperative complications included hypertensive phase (38.1%), corneal decompensation (23.8%), and tube exposure (14.3%).
Conclusion:
An additional AGV implant had good short and modest long-term effectiveness in reducing IOP following a failed glaucoma tube shunt in Asian eyes, with the mentioned common postoperative complications to be actively monitored and managed.