Neonatal hyperglycemia in a preterm infant managed with a subcutaneous insulin pump
Julia D Muzzy Williamson1, Brenda Thurlow2, Mohamed W Mohamed2
1Sanford Children's Hospital, Fargo, ND, and Department of Pharmacy Practice, North Dakota State University, Fargo, ND.
Purpose:
Successful use of a subcutaneous insulin pump to administer regular insulin to a preterm infant with neonatal hyperglycemia is described.
Summary:
A 520-g female infant born at 23 weeks' gestational age via caesarian section was noted to have elevated blood glucose concentrations ranging up to 180 mg/dL (in SI units, 10 mmol/L) on day of life (DOL) 3 and peaking on DOL 9 at 250 mg/dL (13.9 mmol/L) despite conservative glucose infusion rates. Continuous infusion of regular insulin was begun on DOL 8 and continued through DOL 44, with an average insulin infusion rate of 0.08 units/kg/h. The patient experienced blood glucose concentration lability due to multiple factors, resulting in the need for frequent and routine blood glucose concentration monitoring to minimize hypoglycemia events. On DOL 44, a subcutaneous insulin pump was placed and used to provide diluted regular insulin (25 units/mL). After 1 week, the patient's blood glucose concentration normalized, which led to a reduction in the frequency of glucose monitoring. After 3 weeks, insulin pump use was discontinued. The patient remained euglycemic thereafter.
Conclusion:
The use of an insulin pump resulted in decreased blood glucose checks, discontinuation of central line access, and overall better patient care.
Related Concept Videos
Hypoglycemia and Glucagon
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Diabetes Mellitus: Type 2 and Gestational
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Oral Hypoglycemic Agents: Glinides