Defining New Limits in Gas Separations Using Modified ZIF Systems
Panagiotis Krokidas1, Salvador Moncho2, Edward N Brothers2
1Chemical Engineering Program, Texas A&M University at Qatar, P.O. Box 23874, Education City, Doha, Qatar.
Abstract:
Zeolitic-imidazolate frameworks (ZIFs) are candidate materials for the next generation of membranes for cheaper, "greener" separations. More than a decade after ZIF introduction, the high propylene/propane selectivity of ZIF-8 and ZIF-67 is the only example of ZIF membranes with remarkable selectivity efficiency despite their numerous advantages over other families of materials. Herein, we demonstrate the effectiveness of molecular-scale modification in the design of new ZIF materials useful for the separation of important and highly challenging mixtures such as He/CH4, H2/CH4, O2/N2, CO2/CH4, and CO2/N2. Via computational methods, metal and linker substitutions are employed to produce new ZIF-8 variants with a finely discretized range of aperture sizes, as these govern the kinetic-based selectivity of the material. The permeability and selectivity through the ZIF-8 variants of the gases under study are estimated, and their performance is compared with an extensive number of polymeric, metal-organic framework, covalent-organic framework, and mixed-matrix membranes. The comparison shows that some of the ZIF-8 analogues can be used as membranes of unprecedented high separation performance. The scope of this work is to highlight the effectiveness of the molecular level design as means of membrane development to address the global need for cheaper separation methods and CO2 emission reduction.
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...