Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Quasi-Stop-Flow Modulation Strategy for Comprehensive Two-Dimensional Gas Chromatography
Xiaosheng Guan1, Jim Luong2,3, Ziwei Yu1
1J&X Technologies, 1599 Jungong Road, Yangpu District, 200433, Shanghai, China.
Abstract:
An easy-to-implement strategy of differential flow modulation for comprehensive two-dimensional gas chromatography was innovated. With this approach, an independent auxiliary pneumatic control device for flow modulation was not a prerequisite. The strategy involved splitting the carrier gas stream into two separate streams before reaching the inlet embodiment. One stream was employed as a mobile phase for chromatographic separation. The other stream, for flow modulation, was routed to one of the ports of a three-way solenoid valve. The modulation stream flowed onward to a fluidic path and a T-junction that joined the primary and secondary dimension columns. With this arrangement and depending on the configuration of the three-port valve, the analytical platform can be operated in three different modes: bypass stop-flow, vent stop-flow, and quasi-stop flow. Quasi-stop-flow mode was demonstrated to have a significantly better chromatographic performance, as demonstrated in various types of real-life petroleum samples such as gasoline and light cycle oil. In the light cycle oil sample, a respectable separation between compound classes was achieved with peak width at half height of 34 ms or less for alkanes on a second dimension with polyethylene glycol stationary phase. Excellent repeatability was shown with normal alkanes standards of nC8-nC25. Relative standard deviations for retention times are almost zero in 1D, less than 0.2% in 2D, and less than 3.5% for peak areas (n = 9).
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II