Coordination breakdowns in nuclear power plant control rooms: cause identification and behaviour-sequence analysis.

Dunxing Wang1,2, Qin Gao2, Haibo Tan1

  • 1State Key Laboratory of Nuclear Power Safety Monitoring Technology and Equipment, China Nuclear Power Engineering Co. Ltd., Shenzhen, Guangdong Province, P. R. China.

Ergonomics
|April 14, 2020
PubMed
Summary

Effective coordination in nuclear power plant (NPP) control rooms relies on specific behavioral patterns. Higher-performing teams exhibit adaptive workload management and proactive monitoring to prevent coordination breakdowns during emergencies.

Related Concept Videos

Nuclear Power02:36

Nuclear Power

Controlled nuclear fission reactions are used to generate electricity. Any nuclear reactor that produces power via the fission of uranium or plutonium by bombardment with neutrons has six components: nuclear fuel consisting of fissionable material, a nuclear moderator, a neutron source, control rods, reactor coolant, and a shield and containment system.
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
9.2K
Multimachine Stability01:25

Multimachine Stability

Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
492
Zones of Protection01:16

Zones of Protection

In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
695
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
472
Elements of Block Diagrams01:25

Elements of Block Diagrams

Block diagrams serve as a visual representation of the input-output relationships within a system. An illustrative example is a heating system, where the set temperature activates the furnace to warm the room to the desired level. Block diagrams are versatile, modeling linear systems through Laplace transform variables and nonlinear systems using time domain variables.
A block diagram typically includes essential elements such as comparators, blocks, and feedback loops. Each of these elements...
590
Block Diagram Reduction01:22

Block Diagram Reduction

The process of deriving the transfer function of a control system often involves reducing its block diagram to a single block. This simplification can be achieved through a series of strategic operations, including relocating branch points and comparators. These operations preserve the overall function of the system while allowing for easier manipulation and combination of blocks.
The first step in this process is the identification and relocation of a branch point. A branch point, where a...
442