Gillian Ainslie-McLaren1, Angela Fee1, June McKinstray1
1Department of Nuclear Medicine, Stobhill Ambulatory Care Hospital.
Nuclear Medicine Communications
|April 14, 2020
Summary
A new red blood cell volume measurement technique using Indium-111 chloride and tropolone offers a stable alternative to outdated chromium-51 chromate methods, especially for patients with enlarged spleens.
Area of Science:
- Nuclear medicine
- Hematology
- Medical diagnostics
Background:
- Chromium-51 chromate, a traditional method for red blood cell volume measurement, is no longer available.
- Technetium-99m erythrocyte labeling, a common replacement, suffers from known dissociation issues over time.
- A stable and reliable alternative is needed for accurate red blood cell volume determination.
Purpose of the Study:
- To investigate the efficacy and stability of a novel red blood cell labeling technique using Indium-111 chloride and tropolone.
- To evaluate this new method as a viable replacement for Chromium-51 chromate in measuring red blood cell volume.
- To assess the suitability of the Indium-111 tropolone method for clinical use, particularly in patients requiring delayed sampling.
Main Methods:
- In vitro and in vivo studies were conducted to assess the stability and performance of the Indium-111 chloride and tropolone red blood cell labeling technique.
- Radio-labeled product stability was specifically checked at the one-hour time point post-labeling.
- The technique was applied to 20 patients to evaluate its clinical applicability and compare it with previous methods.
Main Results:
- The Indium-111 tropolone red blood cell label demonstrated stability over the tested time period (at least one hour).
- Clinical application in 20 patients indicated that the technique is a viable alternative for red blood cell volume measurement.
- The method proved particularly effective for patients with splenomegaly who necessitate late sampling.
Conclusions:
- Indium-111 chloride and tropolone is a stable and effective radio-labeling agent for red blood cell volume measurement.
- This technique presents a clinically viable alternative to the withdrawn Chromium-51 chromate method.
- The Indium-111 tropolone method is suitable for routine clinical use, especially in specific patient populations like those with splenomegaly.