Atmospheric pressure ionization mass spectrometry as a tool for structural characterization of lignin

Alena Kubátová1, Anastasia A Andrianova1, Joshua Hatton1

  • 1Department of Chemistry, University of North Dakota, 151 Cornell St., Stop 9024, Grand Forks, ND, 58202, USA.

Abstract

Related Concept Videos

Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
1.3K
Matrix-Assisted Laser Desorption Ionization (MALDI)01:08

Matrix-Assisted Laser Desorption Ionization (MALDI)

Matrix-assisted laser desorption ionization (MALDI) is a powerful analytical technique used in mass spectrometry. It enables the identification and characterization of various biomolecules, including proteins, peptides, nucleic acids, and carbohydrates. MALDI is an ionization technique, widely employed in biological and medical research, as well as in fields like pharmacology and biochemistry.The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix...
851
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
1.6K
Mass Spectrometry: Aromatic Compound Fragmentation01:23

Mass Spectrometry: Aromatic Compound Fragmentation

Upon ionization, aromatic compounds generate a molecular ion that is observed as a prominent peak in their mass spectra. For example, the molecular ion peak for benzene appears at a mass-to-charge ratio of 78, while toluene is observed at a mass-to-charge ratio of 92. The molecular ion benzene is highly stable and does not readily undergo further fragmentation due to the significant amount of energy required to disrupt the aromatic stability of the benzene ring. In contrast, the molecular ion...
2.3K
Mass Spectrometry: Overview01:19

Mass Spectrometry: Overview

Mass spectrometry is an analytical technique used to determine the molecular mass and molecular formula of a compound. The basic principle of mass spectrometry is to generate ions from the analyte molecule and measure these ion abundances against their molecular mass. One common type of ionization, known as electron ionization or EI, bombards the analyte molecules in the gas phase with high-energy electron beams. The electron beams displace an electron from the molecule and leave behind a...
8.0K
Mass Spectrometry: Molecular Fragmentation Overview01:20

Mass Spectrometry: Molecular Fragmentation Overview

The ionization of a molecule into a molecular ion inside the mass spectrometer causes instability in the molecule's structure due to the loss of an electron. This eventually leads to the fragmentation or breaking of some bonds in the molecule. The fragmentation occurs predominantly at specific bonds to yield relatively stable fragments.
One type of fragmentation pattern is the cleavage of a single bond in the molecular ion. The cleavage leads to a radical and a cation. The cleavage can occur at...
5.2K