Related Experiment Video
Updated: Dec 24, 2025

Effects of a Novel Neuromuscular Training Intervention on Jump, Sprint, and Change of Direction in Adult Female Soccer Players
Published on: June 10, 2025
Low-Pass Filter Effects on Metrics of Countermovement Vertical Jump Performance
John R Harry1, Jarrod Blinch2, Leland A Barker3
1Human Performance & Biomechanics Laboratory, Department of Kinesiology & Sport Management, Texas Tech University, Lubbock, Texas.
Abstract:
Harry, JR, Blinch, J, Barker, LA, Krzyszkowski, J, and Chowning, L. Low-pass filter effects on metrics of countermovement vertical jump performance. J Strength Cond Res 36(5): 1459-1467, 2022-Countermovement vertical jump (CMVJ) studies using ground reaction force (GRF) data analyze either unfiltered (i.e., raw) or filtered data while providing little-to-no justification for the selected filtering process. Inappropriate filter choices can lead to inaccurate study results and erroneous interpretations. We examined the effects of not filtering GRF data in comparison with filtering data with various objectively and subjectively selected cutoff frequencies. Twenty-one collegiate male basketball players completed 3 maximal-effort CMVJ trials while GRF data were obtained from 2 force platforms. Countermovement vertical jump performance, explosiveness, power output, and neuromuscular function variables were compared among the following methods using one-way repeated-measures analyses of variance (α = 0.05): no filtering (raw data), a standard 50-Hz cutoff (50 Hz), a visually determined cutoff frequency describing the frequency band containing the majority of the summed (visual inspection 1) or not-summed (visual inspection 2) GRF signal's frequency content, filtering the summed (99% signal power 1) or not-summed (99% signal power 2) GRF using a cutoff frequency retaining 99% of the signal power. The raw data method produced significantly shorter concentric phase times and significantly greater center of mass flight heights (∼3%), modified reactive strength indices (RSIMOD; ∼4%), power outputs (∼6%), and push-off distances (∼4%) than 99% signal power 1 and 2 (p < 0.05). Discrete GRF and phase-specific yank magnitudes were not different among methods (p ≥ 0.05). Importantly, no differences were detected between the raw data and 50 Hz methods for any variable (p > 0.05). Low-pass filtering is not necessary when analyzing GRF data from the CMVJ. However, a low-pass filter with a 50-Hz cutoff can remove noise without altering results when compared with raw data. Explicit methodological descriptions of filtering processes should always be provided to improve the integrity of future CMVJ analyses, comparisons among various studies' results, or both.
More Related Videos
08:21Non-invasive Assessments of Subjective and Objective Recovery Characteristics Following an Exhaustive Jump Protocol
Published on: June 8, 2017
06:28Biomechanical Changes Related to Low Back Pain: An Innovative Tool for Movement Pattern Assessment and Treatment Evaluation in Rehabilitation
Published on: December 13, 2024
Related Concept Videos
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...