Related Experiment Video
Updated: Dec 24, 2025

Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
Published on: April 13, 2013
Prediction of an Acute Hypotensive Episode During an ICU Hospitalization With a Super Learner Machine-Learning
Ményssa Cherifa1,2,3, Alice Blet3,4,5, Antoine Chambaz2,3,6
1From the Université de Paris, Paris, France.
Background:
Acute hypotensive episodes (AHE), defined as a drop in the mean arterial pressure (MAP) <65 mm Hg lasting at least 5 consecutive minutes, are among the most critical events in the intensive care unit (ICU). They are known to be associated with adverse outcome in critically ill patients. AHE prediction is of prime interest because it could allow for treatment adjustment to predict or shorten AHE.
Methods:
The Super Learner (SL) algorithm is an ensemble machine-learning algorithm that we specifically trained to predict an AHE 10 minutes in advance. Potential predictors included age, sex, type of care unit, severity scores, and time-evolving characteristics such as mechanical ventilation, vasopressors, or sedation medication as well as features extracted from physiological signals: heart rate, pulse oximetry, and arterial blood pressure. The algorithm was trained on the Medical Information Mart for Intensive Care dataset (MIMIC II) database. Internal validation was based on the area under the receiver operating characteristic curve (AUROC) and the Brier score (BS). External validation was performed using an external dataset from Lariboisière hospital, Paris, France.
Results:
Among 1151 patients included, 826 (72%) patients had at least 1 AHE during their ICU stay. Using 1 single random period per patient, the SL algorithm with Haar wavelets transform preprocessing was associated with an AUROC of 0.929 (95% confidence interval [CI], 0.899-0.958) and a BS of 0.08. Using all available periods for each patient, SL with Haar wavelets transform preprocessing was associated with an AUROC of 0.890 (95% CI, 0.886-0.895) and a BS of 0.11. In the external validation cohort, the AUROC reached 0.884 (95% CI, 0.775-0.993) with 1 random period per patient and 0.889 (0.768-1) with all available periods and BSs <0.1.
Conclusions:
The SL algorithm exhibits good performance for the prediction of an AHE 10 minutes ahead of time. It allows an efficient, robust, and rapid evaluation of the risk of hypotension that opens the way to routine use.
More Related Videos
04:09Predicting Treatment Response to Image-Guided Therapies Using Machine Learning: An Example for Trans-Arterial Treatment of Hepatocellular Carcinoma
Published on: October 10, 2018
06:51Development of an Algorithm to Perform a Comprehensive Study of Autonomic Dysreflexia in Animals with High Spinal Cord Injury Using a Telemetry Device
Published on: July 29, 2016
Related Concept Videos
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Acute Kidney Injury I: Introduction