Related Experiment Video
Updated: Dec 24, 2025

Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
Intraoperative Electronic Alerts Improve Compliance With National Quality Program Measure for Perioperative
Sameer Lakha1, Matthew A Levin1,2, Andrew B Leibowitz1
1From the Departments of Anesthesiology, Perioperative and Pain Medicine.
Background:
Reimbursement for anesthesia services has been shifting from a fee-for-service model to a value-based model that ties payment to quality metrics. The Centers for Medicare & Medicaid Service's (CMS) value-based payment program includes a quality measure for perioperative temperature management (Measure #424, Perioperative Temperature Management). Compliance may impose new challenges in clinical practice, data collection, and reporting. We investigated the impact of an electronic decision-support tool on adherence to this emerging standard.
Methods:
In this retrospective observational study, perioperative temperature data were collected from cases eligible for reporting this measure to CMS from a single academic medical center before and after the implementation of an electronic decision-support tool that prompted temperature measurement and maintenance of normothermia. Proportions of measure compliance were assessed using segmented regression analysis. Proportions of intraoperative temperature measurement were also assessed, and multivariable logistic regression was performed to assess the association between patient and surgical factors and measure compliance.
Results:
A total of 24,755 cases eligible for reporting in 2017 were assessed, and 25,274 cases from 2016 were included as an extended baseline. Segmented time-series regression did not show a significant baseline trend in measure compliance. Introduction of the alerts was associated with an increase in overall compliance from 84.4% (95% confidence interval [CI], 83.6%-85.2%) to 92.4% (91.4%-93.4%), and an increase in intraoperative compliance from 26.8% (25.8%-27.8%) to 71.0% (69.6%-72.4%). The association between the alerts and overall compliance was also present on multivariable analysis.
Conclusions:
Implementation of an intraoperative decision-support tool was associated with statistically significant improvement in the maintenance of normothermia in cases eligible for reporting to CMS. This led to improved compliance with Measure #424 and suggests that electronic alerts can help practices improve their performance and payment bonus eligibility.
More Related Videos
04:58Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
05:43Author Spotlight: Improving Lesion Contiguity in Pulmonary Vein Isolation via Proactive Esophageal Cooling
Published on: April 19, 2024
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...