Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging
Published on: April 28, 2022
Coherent anti-Stokes Raman scattering imaging using silicon photomultipliers
Abstract:
Silicon photomultipliers (SiPMs) are an emerging solid-state alternative to photomultiplier tubes (PMTs) for low light detection, with similar gain but lower cost and lower operating voltage. We demonstrate coherent anti-Stokes Raman scattering (CARS) imaging in a side-by-side comparison of an uncooled SiPM with an uncooled multialkali PMT as well as a state-of-the-art cooled GaAsP PMT. We determine the optimum reverse-bias voltage for acquiring the best signal-to-noise ratio (SNR) for CARS imaging of lipids at ${2850}\;{{\rm cm}^{ - 1}}$2850cm-1. We find that despite the higher dark counts, the SNR of CARS images acquired with the uncooled SiPM biased at an optimum voltage is better than that of the multialkali PMT and close to that of the cooled GaAsP PMT (${\sim}{1.5}$∼1.5 and ${\sim}{0.8}$∼0.8 times, respectively). This is due to the higher gain and lower excess noise factor related to the pulse height variability in the SiPM.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...