Wideband Self-Calibration Method of Inductive CTs and Verification of Determined Values of Current and Phase Errors

Ernest Stano1, Michal Kaczmarek1

  • 1Institute of Mechatronics and Information Systems, Lodz University of Technology, Stefanowskiego 18/22 St, 90-924 Lodz, Poland.

Related Concept Videos

Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
601
Instrument Transformers01:23

Instrument Transformers

Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
382
Mesh Analysis for AC Circuits01:12

Mesh Analysis for AC Circuits

In the domain of radio communication, the significance of impedance matching must be considered. It is crucial to ensure the efficient transmission of signals between radio transmitters and receivers. Achieving this balance involves using impedance-matching circuits, with one fundamental configuration comprising a resistor, capacitor, and inductor.
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
607
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
469
Inductance: Single-Phase And Three-Phase Line01:28

Inductance: Single-Phase And Three-Phase Line

Understanding the inductance of transmission lines is crucial for efficient design and operation in electrical power systems. This discussion delves into the inductance characteristics of single-phase two-wire and three-phase three-wire transmission lines with equal phase spacing.
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
543
Source Transformation for AC Circuits01:11

Source Transformation for AC Circuits

The process of source transformation in the frequency domain entails the conversion of a voltage source, positioned in series with an impedance, into a current source that is parallel to an impedance, or the other way around. It is essential to maintain the following relationships while transitioning from one source type to another.
971