Related Experiment Video
Updated: Dec 24, 2025

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
[Determination of diethylenetriamine in workplace air by solvent desorption-gas chromatography]
1Occupational Hygiene Technology Services Co. , Ltd. NHWOC, Zhanjiang 524057, China.
Objective:
To establish solvent desorption gas chromatograph method for diethylenetriamine determination in workplace air.
Methods:
Diethylenetriamine in workplace air was collected with alkaline silicone tube, and desorbed with 0. 2 mol/L methanol solution of hydrochloric acid. After centrifugation, the supernatant neutralized with 0. 3 mol/L methanol solution of potassium hydroxide, was separated with 5%-phenyl-methyl polysiloxane(HP-5)(25 m×0. 32 mm×0. 52 mm)and measured with flame ionization detector.
Results:
Detection limit of the method was 0. 49 μg/mL, quantification limit of the method was 1. 64 μg/mL, quantitative determination range of method was 1. 64-233. 80 μg/mL, and the minimum quantitative determination concentration was 0. 22 mg/m~3(based on 7. 5 L sample). The method had a good reproducibility, the relative standard deviation was 1. 4%-3. 3%, the average of desorption efficiency was 90. 8%, and the average of sampling efficiency was 93. 2%. The penetrating capacity of 200 mg alkaline silicone was over than 7. 1 mg, and the samples at room temperature could be preserved for 15 days at least. Ethylenediamine, triethylenetetramine or tetraethylenepentamine coexisted in the air did not interfere during the determination of diethylenetriamine.
Conclusion:
The method with low determination concentration, high accuracy and precision, is feasible for determination of diethylenetriamine in workplace air.
More Related Videos
04:19Author Spotlight: An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023
07:32Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...