Oxidative Catalysis by TAMLs: Obtaining Rate Constants for Non-Absorbing Targets by UV-Vis Spectroscopy

Yogesh Somasundar1, Iris C Lu1, Matthew R Mills1

  • 1Institute for Green Science, Department of Chemistry, Carnegie Mellon University, 4400 Fifth Ave, Pittsburgh, PA 15213, USA.

Related Concept Videos

Measuring Reaction Rates03:09

Measuring Reaction Rates

Polarimetry finds application in chemical kinetics to measure the concentration and reaction kinetics of optically active substances during a chemical reaction. Optically active substances have the capability of rotating the plane of polarization of linearly polarized light passing through them—a feature called optical rotation. Optical activity is attributed to the molecular structure of substances. Normal monochromatic light is unpolarized and possesses oscillations of the electrical...
28.4K
Catalysis02:50

Catalysis

The presence of a catalyst affects the rate of a chemical reaction. A catalyst is a substance that can increase the reaction rate without being consumed during the process. A basic comprehension of a catalysts’ role during chemical reactions can be understood from the concept of reaction mechanisms and energy diagrams.
29.9K
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview01:02

Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview

Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material,  molecules absorb light depending on the energy required for...
4.2K
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
3.2K
Catalytically Perfect Enzymes01:07

Catalytically Perfect Enzymes

The theory of catalytically perfect enzymes was first proposed by W.J. Albery and J. R. Knowles in 1976. These enzymes catalyze biochemical reactions at high-speed. Their catalytic efficiency values range from 108-109 M-1s-1. These enzymes are also called 'diffusion-controlled' as the only rate-limiting step in the catalysis is that of the substrate diffusion into the active site. Examples include triose phosphate isomerase, fumarase, and superoxide dismutase.
 
Most enzymes...
4.8K
Introduction to Enzyme Kinetics01:19

Introduction to Enzyme Kinetics

Enzyme kinetics studies the rates of biochemical reactions. Scientists monitor the reaction rates for a particular enzymatic reaction at various substrate concentrations. Additional trials with inhibitors or other molecules that affect the reaction rate may also be performed.
The experimenter can then plot the initial reaction rate or velocity (Vo) of a given trial against the substrate concentration ([S]) to obtain a graph of the reaction properties. For many enzymatic reactions involving a...
31.0K