Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Volume electron microscopy reveals heterogeneity of the hemostatic response in veins and arteries.

Blood advances·2026
Same author

Understanding how a highly prevalent GRK5 polymorphism affects platelets and enhances thrombotic risk.

Blood·2026
Same author

From imaging to computational domains for physics-driven molecular biology simulations: Hindered diffusion in platelet masses.

PLoS computational biology·2025
Same author

From imaging to computational domains for physics-driven molecular biology simulations: Hindered diffusion in platelet masses.

bioRxiv : the preprint server for biology·2025
Same author

Procoagulant membranes during hemostasis.

Blood·2024
Same author

Fluorescent peptide for detecting factor XIIIa activity and fibrin in whole blood clots forming under flow.

Research and practice in thrombosis and haemostasis·2024

Related Experiment Video

Updated: Dec 24, 2025

A Mouse Model for Laser-induced Choroidal Neovascularization
07:08

A Mouse Model for Laser-induced Choroidal Neovascularization

Published on: December 27, 2015

18.6K

Mouse laser injury models: variations on a theme.

Timothy J Stalker1

  • 1Department of Medicine, Perelman School of Medicine, University of Pennsylvania , Philadelphia, PA, USA.

Platelets
|April 17, 2020
PubMed
Summary
This summary is machine-generated.

Laser injury models in mice are crucial for studying hemostasis and thrombosis. This review compares laser injury models, detailing their mechanisms, extent, and vascular applications for better interpretation of thrombosis and hemostasis research.

Keywords:
Hemostasisintravital microscopylaser injurythrombosis

More Related Videos

A Laser-induced Mouse Model of Chronic Ocular Hypertension to Characterize Visual Defects
07:00

A Laser-induced Mouse Model of Chronic Ocular Hypertension to Characterize Visual Defects

Published on: August 14, 2013

13.4K
Optimization of the Retinal Vein Occlusion Mouse Model to Limit Variability
07:23

Optimization of the Retinal Vein Occlusion Mouse Model to Limit Variability

Published on: August 6, 2021

3.1K

Related Experiment Videos

Last Updated: Dec 24, 2025

A Mouse Model for Laser-induced Choroidal Neovascularization
07:08

A Mouse Model for Laser-induced Choroidal Neovascularization

Published on: December 27, 2015

18.6K
A Laser-induced Mouse Model of Chronic Ocular Hypertension to Characterize Visual Defects
07:00

A Laser-induced Mouse Model of Chronic Ocular Hypertension to Characterize Visual Defects

Published on: August 14, 2013

13.4K
Optimization of the Retinal Vein Occlusion Mouse Model to Limit Variability
07:23

Optimization of the Retinal Vein Occlusion Mouse Model to Limit Variability

Published on: August 6, 2021

3.1K

Area of Science:

  • Vascular biology
  • Hemostasis and thrombosis research
  • Animal modeling

Background:

  • Technological advances in genetic manipulation and fluorescence imaging have popularized laser injury models in mice.
  • Accurate interpretation of hemostasis and thrombosis studies relies on understanding experimentally induced vascular injury.
  • Existing literature indicates variability in vascular damage caused by direct laser injury.

Purpose of the Study:

  • To compare and contrast various laser injury models used in hemostasis and thrombosis research.
  • To emphasize the mechanism and extent of vascular injury induced by different laser models.
  • To discuss the application of laser injury in diverse vascular beds and associated molecular responses.

Main Methods:

  • Literature review and comparative analysis of laser injury models.
  • Examination of mechanisms and degrees of vascular damage.
  • Assessment of molecular pathways regulating injury response.

Main Results:

  • Laser-induced vascular injury exhibits variable degrees of damage.
  • Different laser injury models have distinct mechanisms and extents of injury.
  • The application of laser injury models varies across different vascular beds.

Conclusions:

  • Understanding the specifics of laser injury models is critical for accurate hemostasis and thrombosis research.
  • Distinct laser injury applications can represent different aspects of thrombosis and/or hemostasis.
  • This review provides a framework for selecting and interpreting laser injury models in vascular studies.