Related Experiment Video
Updated: Dec 23, 2025

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
Establishment of national diagnostic reference levels for radiotherapy computed tomography simulation procedures in
Nika Zalokar1, Valerija Žager Marciuš2, Nejc Mekiš1
1University of Ljubljana, Faculty of Health Sciences, Medical Imaging and Radiotherapy Department, Zdravstvena pot 5, 1000, Ljubljana, Slovenia.
Purpose:
To propose national diagnostic reference levels (DRLs) for radiotherapy (RT) computed tomography (CT) localization purposes, compare both CT units used in the largest RT department in the country and to compare gathered results with other published DRLs in order to discover any need of optimization.
Methods:
In total, 1631 patient data (time spend of 4 months) regarding sex, examination type, total dose-length product (DLP) and CTDIvol was collated on two CT units. Those simulation procedures account for more than 80 % of all simulation procedures performed nationwide. Then, total DLP and CTDIvol was calculated and mean, median and 3rd quartile for both units together were presented to determine national DRLs for simulation procedures. The same data was later compared between both units to discover any potential need for optimization.
Results:
3rd quartile values of DLP for abdomen, breast, chest, head, head and neck, pelvis and spine were 1116.2, 606.6, 832.4, 1942.4, 969.2, 677.1 and 1042.4 mGy∙cm, respectively. 3rd quartile CTDIvol values for the same sequence of procedures were 18.7, 13.3, 19.2, 76.9, 22.6, 17.9 and 22.2 mGy, respectively. Among the two units, the mentioned dose values were on average significantly higher on one CT unit than on the other unit.
Conclusions:
When comparing collected dose values with other studies, RT CT DRLs showed that radiation doses from our institution were similar or even lower. Some variations were found between both CT units in certain protocols, so exposure parameters should be reviewed and optimized.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...