Related Experiment Video
Updated: Dec 23, 2025

Using 22C3 Anti-PD-L1 Antibody Concentrate on Biopsy and Cytology Samples from Non-small Cell Lung Cancer Patients
Published on: September 25, 2018
Canadian Multicenter Project on Standardization of Programmed Death-Ligand 1 Immunohistochemistry 22C3
Emina Torlakovic1, Roula Albadine2, Gilbert Bigras3
1Department of Pathology and Laboratory Medicine, Royal University Hospital, Saskatchewan Health Authority, Saskatoon, Canada; College of Medicine, University of Saskatchewan, Saskatoon, Canada.
Introduction:
The programmed death-ligand 1 (PD-L1) immunohistochemistry (IHC) assay is used to select patients for first or second-line pembrolizumab monotherapy in NSCLC. The PD-L1 IHC 22C3 pharmDx assay requires an Autostainer Link 48 instrument. Laboratories without this stainer have the option to develop a highly accurate 22C3 IHC laboratory-developed test (LDT) on other instruments. The Canadian 22C3 IHC LDT validation project was initiated to harmonize the quality of PD-L1 22C3 IHC LDT protocols across 20 Canadian pathology laboratories.
Methods:
Centrally optimized 22C3 LDT protocols were distributed to participating laboratories. The LDT results were assessed against results using reference PD-L1 IHC 22C3 pharmDx. Analytical sensitivity and specificity were assessed using cell lines with varying PD-L1 expression levels (phase 1) and IHC critical assay performance controls (phase 2B). Diagnostic sensitivity and specificity were assessed using whole sections of 50 NSCLC cases (phase 2A) and tissue microarrays with an additional 50 NSCLC cases (phase 2C).
Results:
In phase 1, 80% of participants reached acceptance criteria for analytical performance in the first attempt with disseminated protocols. However, in phase 2A, only 40% of participants reached the desired diagnostic accuracy for both 1% and 50% tumor proportion score cutoff. In phase 2B, further protocol modifications were conducted, which increased the number of successful laboratories to 75% in phase 2C.
Conclusions:
It is possible to harmonize highly accurate 22C3 LDTs for both 1% and 50% tumor proportion score in NSCLC across many laboratories with different platforms. However, despite a centralized approach, diagnostic validation of predictive IHC LDTs can be challenging and not always successful.
More Related Videos
10:29Semi-automatic PD-L1 Characterization and Enumeration of Circulating Tumor Cells from Non-small Cell Lung Cancer Patients by Immunofluorescence
Published on: August 14, 2019
09:32Multiplexed Immunofluorescence Analysis and Quantification of Intratumoral PD-1+ Tim-3+ CD8+ T Cells
Published on: February 8, 2018