Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures
Published on: November 21, 2019
Technical note: characterization of spectral changes with measurement geometry and magnetic field strength in light
E Simiele1,2, R-P Kapsch3, U Ankerhold3
1Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI 53705 United States of America.
Abstract:
The purpose of this work was to characterize the stem-effect signal and the Cerenkov light ratio (CLR) in various light guides as functions of measurement geometry and magnetic field strength. Two PMMA-, two silica-, and one polystyrene-based light guides were considered in this work. Spectra measurements were performed as functions of depth, fiber-beam angle, and magnetic field strength using an optical spectrometer. All measurements were performed using a clinical linear accelerator at a nominal photon beam energy of 6 MV. Depths ranging from 1 cm to 10 cm, fiber-beam angles ranging from 90 degrees to 30 degrees, and magnetic field strengths ranging from 0 T to ± 1.40 T were investigated. The CLR was calculated from each spectrum by taking the ratio of the integral signal between 400 nm and 500 nm to the integral signal between 500 nm and 600 nm. A maximum increase of 80.5% in the stem-effect signal was observed in the magnetic field. Variations in spectral shape and, consequently, the CLR were observed for all of the fibers as functions of magnetic field strength and measurement geometry, particularly for wavelengths less than 400 nm. The plastic fibers exhibited decreases in the CLR as a function of magnetic field strength at all depths investigated, whereas the silica fibers exhibited increases in the CLR with decreasing magnetic field strength. A maximum variation of 11.1% in the CLR was observed for the polystyrene fiber due to the magnetic field. The sensitivity of the CLR to the magnetic field decreased as the fiber-beam angle decreased. The measured spectral response, shape, and CLR were found to be sensitive to the applied magnetic field strength and polarity where the variations in response were unique to each fiber.
Related Concept Videos
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
UV–Vis Spectrometers
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
NMR Spectrometers: Resolution and Error Correction