Related Experiment Video
Updated: Dec 23, 2025

Author Spotlight: Introduction to Active Probe Atomic Force Microscopy with Quattro-Parallel Cantilever Arrays
Published on: June 13, 2023
Comparison of acoustic radiation force impulse imaging with the convex probe 6C1 and linear probe 9L4
Mirja Wegner1, Erol Iskender, Ahmed Azzarok
1Academic Teaching Hospital Bethesda Duisburg, Department of Gastroenterology, Duisburg, Germany.
Background:
Acoustic radiation force impulse imaging (ARFI) is a noninvasive method to detect liver fibrosis. The aims of the study were to evaluate the difference between 2 different probes, 6 C1 and 9 L4, and to study inter- and intraobserver reproducibility for the probes.
Methods:
We enrolled 100 patients in this cross-sectional comparative study. All patients underwent liver stiffness measurement with both probes. Intraobserver, interobserver, intralobe, and interlobe agreement was analyzed using the intraclass correlation coefficient.
Results:
A significant difference in success rates was observed for both probes between the right and left liver lobes. A success rate of 91% was observed in the right liver lobe compared with 77% in the left liver for the convex probe (P = .007), and 91% vs 68% for the linear probe (P < .001). There was a significant correlation in ARFI-shear wave velocity (ARFI-SWV) between both probes in the right liver lobe (P = .01; r = .508) and in the left liver lobe (P = .05; r = .278); however, there was no significant correlation in ARFI-SWV between the liver lobes for both probes (convex probe r = .19 P = .112; linear probe r = .144 P = .23). Good or excellent inter- and intraobserver was detected for both probes. Poor agreement was found only for the interobserver agreement in the left lobe with the convex probe (ICC = .320).
Conclusion:
ARFI can be performed successfully with both probes in both liver lobes. There was no significant correlation in ARFI between the liver lobes for both probes; however, the right liver lobe should be favored. Standardization of the procedure is needed for the comparability of different studies.
More Related Videos
09:56Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
Published on: November 4, 2014
16:01An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017
Related Concept Videos
Atomic Force Microscopy
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Overview of Microscopy Techniques