On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
Carbon dots based solid phase microextraction of 2-nitroaniline followed by fluorescence sensing for selective early
Shuqin Liu1, Huangsheng Yang2, Shenghong Yang3
1Guangdong Engineering and Technology Research Center for Ambient Mass Spectrometry, Guangdong Provincial Key Laboratory of Emergency Test for Dangerous Chemicals, Guangdong Institute of Analysis (China National Analytical Center Guangzhou), Guangdong Academy of Sciences, 100 Xianlie Middle Road, Guangzhou, 510070, China.
Abstract:
For decades, researches have been involving in improving and optimizing solid-phase microextraction (SPME) technique to fit the growing environmental analysis demand. But it is more significant now to introduce meaningful information into the analysis line instead of improving every step in SPME. Herein, we design a carbon dots (CDs) based SPME platform and report its unique application in selective early screening and sensitive detection of 2-nitroaniline. The fluorescence quenching state of the CDs fiber after extraction could be used to prejudge whether an environmental sample contains 2-nitroaniline exceeding the maximum permitted level (30 μg L-1) regulated by the Chinese Ministry of Environmental Protection or not. Photo-induced electron transfer (PET) is believed to be the primary quenching route that leads to electron transfer from the electron-rich CDs to the electron-deficient analyte. A preliminary in vivo study on Daphnia magna and a 2-nitroaniline assay in environmental water and biofluid samples suggested the safety and the excellent qualitative ability of the proposed platform. As a result, the innovative incorporation of fluorescence sensing and SPME not only achieves the information imbedding of environmental analysis system, but also combines the advantages of two techniques including early visual-screening, reusability (≥50 times), high specificity and excellent quantitative ability (detection limit: 0.011 μg L-1). We believe this study can open new avenues in the field of environmental toxicant monitoring.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....