Related Experiment Video
Updated: Dec 23, 2025

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Flexion First Balancer: description of new technique in TKA to reproduce joint line and pre-disease mechanical
W A M van Lieshout1, K L M Koenraadt2, L H G J Elmans3
1Dept. Orthopedic surgery, Amphia Hospital, Molengracht 21, 4818, CK, Breda, The Netherlands. wvanlieshout@gmail.com.
Abstract:
A considerable proportion of patients (19%) are dissatisfied after total knee arthroplasty (TKA). Possible factors contributing to this dissatisfaction are decreased posterior condylar offset (PCO) with subsequent joint line elevation, leading to mid-flexion instability. Secondly, the pre-disease mechanical alignment is changed into a neutral alignment. The Flexion First Balancer was developed to avoid these problems. This technique aims to maintain MCL isometry by restoring medial PCO and medial joint line to its pre-disease level. Also, to reconstruct the pre-disease mechanical alignment by adjusting the distal femoral angle. In this study we provide a detailed technical overview of the Flexion First Balancer technique.