Optimum Cell Pathlength or Volume for Absorbance Detection in Liquid Chromatography: Transforming Longer Cell Results
Akinde F Kadjo1, Purnendu K Dasgupta1, Charles Phillip Shelor1
1Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, Texas 76019-0065, United States.
Abstract:
The cell volume permissible for a specified degree of loss of efficiency can be computed from response volume considerations. For an open tubular column, the permissible illuminated length can be computed for the unretained peak. Similar estimations can be made for the maximum permissible cell volume with a packed column for a given column efficiency and flow rate. The packed column case does require an assumption on the degree to which the cell behaves as a mixer. An altogether different question is if the data from a long cell, with its considerable advantage in S/N, can be used and the associated dispersion mathematically removed. Experimental data for a variable path length (0-60 mm) HPLC detection cell indicate that an exponential model fits the observed dispersion. Once fit parameters are determined, the same can be applied to a peak, not part of the original training set, obtained in a longer path cell and the effects of dispersion mathematically reversed without major loss of S/N. Results with shorter path cell dispersion characteristics are then obtained with much higher S/N. A comparison is made with Fourier transform-inverse Fourier transform based deconvolution that can be used to achieve the same ends.
More Related Videos
09:04Lens-free Video Microscopy for the Dynamic and Quantitative Analysis of Adherent Cell Culture
Published on: February 23, 2018
07:55Integrated Cell Manipulation Platform Coupled with the Single-probe for Mass Spectrometry Analysis of Drugs and Metabolites in Single Suspension Cells
Published on: June 21, 2019
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Methods: Terminology
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation