Related Experiment Video
Updated: Dec 23, 2025

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Rationale for using the velocity-time integral and the minute distance for assessing the stroke volume and cardiac
1Intensive Care Physician, Intensive Care Unit, Clínica Cruz Azul, 2651, 60 St., 7630, Necochea, Argentina. ohtusabes@gmail.com.
Background:
Stroke volume (SV) and cardiac output (CO) are basic hemodynamic parameters which aid in targeting organ perfusion and oxygen delivery in critically ill patients with hemodynamic instability. While there are several methods for obtaining this data, the use of transthoracic echocardiography (TTE) is gaining acceptance among intensivists and emergency physicians. With TTE, there are several points that practitioners should consider to make estimations of the SV/CO as simplest as possible and avoid confounders.
Main Body:
With TTE, the SV is usually obtained as the product of the left ventricular outflow tract (LVOT) cross-sectional area (CSA) by the LVOT velocity-time integral (LVOT VTI); the CO results as the product of the SV and the heart rate (HR). However, there are important drawbacks, especially when obtaining the LVOT CSA and thus the impaction in the calculated SV and CO. Given that the LVOT CSA is constant, any change in the SV and CO is highly dependent on variations in the LVOT VTI; the HR contributes to CO as well. Therefore, the LVOT VTI aids in monitoring the SV without the need to calculate the LVOT CSA; the minute distance (i.e., SV × HR) aids in monitoring the CO. This approach is useful for ongoing assessment of the CO status and the patient's response to interventions, such as fluid challenges or inotropic stimulation. When the LVOT VTI is not accurate or cannot be obtained, the mitral valve or right ventricular outflow tract VTI can also be used in the same fashion as LVOT VTI. Besides its pivotal role in hemodynamic monitoring, the LVOT VTI has been shown to predict outcomes in selected populations, such as in patients with acute decompensated HF and pulmonary embolism, where a low LVOT VTI is associated with a worse prognosis.
Conclusion:
The VTI and minute distance are simple, feasible and reproducible measurements to serially track the SV and CO and thus their high value in the hemodynamic monitoring of critically ill patients in point-of-care settings. In addition, the LVOT VTI is able to predict outcomes in selected populations.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Velocity and Position by Graphical Method
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Average and Instantaneous Velocity Vectors
Velocity and Position by Integral Method
Consider an example to calculate the velocity and position from the acceleration function. A motorboat is traveling at a constant velocity of 5.0 m/s when it starts to decelerate to arrive at the dock. Its acceleration is...

