How His bundle pacing prevents and reverses heart failure induced by right ventricular pacing
Alfred Stanley1, Constantine Athanasuleas2, Gerald Buckberg3
1Cardiovascular Associates of the Southeast, Birmingham, AL, USA.
Abstract:
Ideal heart performance demands vigorous systolic contractions and rapid diastolic relaxation. These sequential events are precisely timed and interdependent and require the rapid synchronous electrical stimulation provided by the His-Purkinje system. Right ventricular (RV) pacing creates slow asynchronous electrical stimulation that disrupts the timing of the cardiac cycle and results in left ventricular (LV) mechanical asynchrony. Long-term mechanical asynchrony produces LV dysfunction, remodeling, and clinical heart failure. His bundle pacing preserves synchronous electrical and mechanical LV function, prevents or reverses RV pacemaker-induced remodeling, and reduces heart failure.