Related Experiment Video
Updated: Dec 23, 2025

Oral Biofilm Formation on Different Materials for Dental Implants
Published on: June 24, 2018
Monolithic Screw-Retained Lithium Disilicate Implant Crowns: Preliminary Data of a Prospective Cohort Study
Purpose:
To analyze the clinical behavior of screw-retained monolithic lithium disilicate (LDS) implant-supported single crowns (ISSCs) over a 1-year follow-up.
Materials And Methods:
A total of 28 patients were restored with 45 screw-retained monolithic LDS (press-fabricated) ISSCs bonded to titanium bases in posterior sites. Modified United States Public Health Service criteria and Kaplan-Meier survival and success rates were evaluated.
Results:
A total of 27 patients with 44 ISSCs were evaluated 12 months (mean ± standard deviation: 13.02 ± 2.28) after prosthesis delivery. No implant or crown failures occurred. The Kaplan-Meier survival and success rates were each 100% after 1 year. Minorly increased surface roughness was noted in the occlusal contact point areas of 9 ISSCs (20.5% Bravo rating). Marginal adaptation, color match, and anatomical form stayed favorable over time.
Conclusion:
Press-fabricated LDS monolithic screw-retained implant crowns appear to be a promising treatment option for posterior implants under short-term observation.