Examining Reliability and Validity of the Jebsen-Taylor Hand Function Test Among Children With Cerebral Palsy
M Tofani1, E Castelli1, M Sabbadini1
1Neurorehabilitation Unit, Department of Neurosciences and Neurorehabilitation, Bambino Gesù Children's Hospital, Rome, Italy.
Insights
The Jebsen-Taylor Hand Function Test (JTHFT) demonstrates strong validity and internal consistency for assessing manual dexterity in children with cerebral palsy (CP). This tool is reliable for evaluating hand function in children aged 6-18 years.
Area of Science:
- Pediatric Rehabilitation
- Neuroscience
- Occupational Therapy
Background:
- Manual dexterity is crucial for daily living activities in children with cerebral palsy (CP).
- The Jebsen-Taylor Hand Function Test (JTHFT) is a common tool for assessing manual dexterity, but its psychometric properties in CP populations are not well-established.
- Understanding the validity and reliability of assessment tools is essential for effective intervention planning.
Purpose of the Study:
- To evaluate the psychometric properties, specifically validity and internal consistency, of the Jebsen-Taylor Hand Function Test (JTHFT).
- To determine if the JTHFT is a suitable assessment tool for manual dexterity in children diagnosed with cerebral palsy (CP).
- To examine the correlation between JTHFT scores and the Manual Ability Classification System (MACS) in pediatric CP patients.
Main Methods:
- A cross-sectional study involving 84 children (6-18 years) with cerebral palsy (CP).
- Internal consistency was assessed using Cronbach's alpha for both dominant and nondominant hands.
- Validity was tested by correlating JTHFT scores with the Manual Ability Classification System (MACS) using Pearson's correlation coefficient.
Main Results:
- The JTHFT exhibited excellent internal consistency, with Cronbach's alpha values of .944 (nondominant hand) and .911 (dominant hand).
- A statistically significant positive linear correlation was found between JTHFT scores and MACS levels (p < .01), indicating good validity.
- High variability in writing performance (JTHFT Item 1) was noted across different MACS levels.
Conclusions:
- The Jebsen-Taylor Hand Function Test (JTHFT) is confirmed as a valid and reliable instrument for assessing manual dexterity in children with cerebral palsy (CP) aged 6-18 years.
- The findings support the use of JTHFT in clinical and research settings for evaluating hand function in this population.
- Further investigation into specific test items, like writing, may provide deeper insights into functional limitations.
Abstract:
Manual dexterity has strongly predicted functional independence for daily life activities among children with cerebral palsy (CP). The Jebsen-Taylor Hand Function Test (JTHFT) is the most widely used assessment tool for exploring manual dexterity in the CP population, though no research has yet examined its psychometric properties for this use. This cross-sectional study explored the validity and internal consistency of the JTHFT in an Italian sample of inpatient and outpatient children with CP aged between 6-18 years (35 girls and 49 boys). We calculated internal consistency with Cronbach's alpha and tested validity against the Manual Ability Classification System (MACS) using Pearson's correlation coefficient. To better understand how the JTHFT compares with different levels of the MACS, we performed dominant hand timing variability for each test item. Results showed excellent internal consistency with a Cronbach's alpha of .944 and .911, respectively, for nondominant and dominant hands. There was also a statistically significant positive linear Pearson's correlation coefficient between the JTHFT and the MACS (p < .01). We observed high variability in writing performance (Item 1 of the JTHFT) within this sample for each level of the MACS. This study confirms that the JTHFT is a valid assessment tool when used in children with CP aged 6-18 years.
More Related Videos
07:20Author Spotlight: Repetitive Transcranial Magnetic Stimulation Combined with Movement Observation in Cerebral Palsy
Published on: August 9, 2024
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019