Related Experiment Video
Updated: Dec 23, 2025

Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
Analysis on the Temperature Field and the Ampacity of XLPE Submarine HV Cable Based on Electro-Thermal-Flow
Yiyi Zhang1, Xiaoming Chen1, Heng Zhang1
1College of Electrical Engineering, Guangxi University, Nanning 530004, Guangxi, China.
Abstract:
The operating temperature and the ampacity are important parameters to reflect the operating state of cross-linked polyethylene (XLPE) submarine high voltage (HV) cables, and it is of great significance to study the electrothermal coupling law of submarine cable under the seawater flow field. In this study, according to the actual laying conditions of the submarine cable, a multi-physical coupling model of submarine cable is established based on the electromagnetic field, heat transfer field, and fluid field by using the COMSOL finite element simulation software. This model can help to analyze how the temperature and ampacity of the submarine cable are affected by different laying methods, seawater velocity, seawater temperature, laying depth, and soil thermal conductivity. The experimental results show that the pipe laying method can lead to the highest cable conductor temperature, even exceeding the maximum heat-resistant operating temperature of the insulation, and the corresponding ampacity is minimum, so heat dissipation is required. Besides, the conductor temperature and the submarine cable ampacity have a linear relationship with the seawater temperature, and small seawater velocity can significantly improve the submarine cable ampacity. Temperature correction coefficients and ampacity correction coefficients for steady-state seawater are proposed. Furthermore, the laying depth and soil thermal conductivity have great impact on the temperature field and the ampacity of submarine cable, so measures (e.g., artificial backfilling) in areas with low thermal conductivity are needed to improve the submarine cable ampacity.
Related Concept Videos
Cable Subjected to a Distributed Load
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Maximum Power Flow and Line Loadability
Cable Subjected to Concentrated Loads
Cable: Problem Solving
Transmission-Line Differential Equations
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured from...