When they stop drinking-examining end-of-life hydration practices and death rattle occurrence
Daniel Dayan1,2, Sasson Menahem3,4,5, Pesach Shvartzman4,5
1Department of Family Medicine, Division of Community Health, Faculty of Health Sciences, Ben-Gurion University of the Negev, POB 653, 84105, Beer-Sheva, Israel. dayandan@post.bgu.ac.il.
Purpose:
To characterize the practice of subcutaneous hydration provision in the Beer-Sheva home care hospice unit. We also explore the potential connection between the provision of subcutaneous hydration and the incidence of death rattle.
Methods:
This was a prospective observational study involving 120 hospice patients. During the 6 days before death, hospice staff recorded whether or not fluids were administered orally and/or subcutaneously; the duration, timing, and quantity of fluid administration; the incidence, timing, and duration of death rattle; and whether medications that can affect death rattle were given.
Result:
Fifty-three percent of the patients received subcutaneous hydration. The mean daily volume administered in the hydration group was 434 ml. There was a significant association between the duration of treatment in the hospice unit and provision of subcutaneous hydration (mean of 51 days in hydration group vs. 31 days in non-hydration group, p = 0.03). Although not statistically significant, males were more likely to receive subcutaneous hydration than females (62% of males vs. 46% of females, p = 0.09). There was a higher incidence of death rattle in men compared to women (54.7% in men vs. 32.8% in women, p = 0.025). A statistically significant association between death rattle and the provision of subcutaneous hydration wasn't demonstrated.
Conclusion:
The decision of whether to provide subcutaneous hydration is individualized taking into consideration the values of the patients and their families. The provision of 500 ml per day of subcutaneous saline during the last 6 days of life does not significantly increase the incidence of death rattle.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Acute Respiratory Failure-IV
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy Suctioning II: Procedure