Related Experiment Video
Updated: Dec 23, 2025

The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Disinfection of surfaces contaminated with Clostridioides difficile endospores using NaCl-derived electrochemically
A Medaglia-Mata1, R Starbird-Pérez2, E Sánchez-Chacón3
1Laboratorio Institucional de Microscopía and Escuela de Biología, Instituto Tecnológico de Costa Rica, Cartago, Costa Rica.
Background:
Clostridioides difficile is transmitted through endospores. Most disinfection procedures for these structures deploy high concentrations of chlorine-derived compounds such as sodium hypochlorite (NaOCl) and sodium dichloroisocyanurate (NaDCC). However, these substances are linked to undesirable public health and environmental issues.
Aim:
To compare the efficacy of NaCl-derived electrochemically activated solution (ECAS, 0.18% w/v NaOCl, pH=9.6-10.3), commercial bleach (5000 ppm, 2.83% w/v NaOCl, pH=5.6) and NaDCC (1000 ppm, pH=6.8) to inactivate C. difficile endospores on surfaces using a standard quantitative test (EPA MO-21-03).
Findings:
Ten representative reference and field strains from multi-locus sequence typing Clades 1-5 were assayed (N=10). Irrespective of the phylogenetic background of the strains, ECAS showed comparable or better log reduction values [mean=3.22, 95% confidence interval (CI) 0.40-5.56] than bleach (mean=2.74, 95% CI 0.12-5.50) and NaDCC (mean=2.02, 95% CI 0.10-5.12). Cyclic voltammetry measurements revealed similar electrochemical behaviours and open-circuit potentials for ECAS and NaOCl. Congruently, similar morphologies for spores treated with these two compounds were observed by transmission electron microscopy. A factorial design demonstrated that exposure time, but not activation time, influenced the efficacy of ECAS.
Conclusions:
ECAS and NaOC were found to have functional equivalence and may have a common mechanism of action.
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Chemical Agents for Microbial Control
Endospores and Sporulation
Hand hygiene
Hand washing...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...