Related Experiment Video
Updated: Dec 23, 2025

09:33
Demonstration of Equal-Intensity Beam Generation by Dielectric Metasurfaces
Published on: June 7, 2019
6.6K
The advantages of metalenses over diffractive lenses
1Department of Applied Physics, The Faculty of Science, The Center for nanoscience and nanotechnology, The Hebrew University Jerusalem, 91904, Jerusalem, Israel.
Nature Communications
|April 26, 2020
Abstract
No abstract available in PubMed .
More Related Videos
Related Concept Videos
Focusing of Light in the Eye
4.9K
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
4.9K
Confocal Fluorescence Microscopy
19.7K
Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
19.7K
Phase Contrast and Differential Interference Contrast Microscopy
11.8K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
11.8K
Metal-Semiconductor Junctions
794
The contact of metal and semiconductor can lead to the formation of a junction with either Schottky or Ohmic behavior.
Schottky Barriers
Schottky barriers arise when a metal with a work function (Φm) contacts a semiconductor with a different work function (Φs). Initially, electrons transfer until the Fermi levels of the metal and semiconductor align at equilibrium. For instance, if Φm > Φs, the semiconductor Fermi level is higher than the metal's before contact. The...
Schottky Barriers
Schottky barriers arise when a metal with a work function (Φm) contacts a semiconductor with a different work function (Φs). Initially, electrons transfer until the Fermi levels of the metal and semiconductor align at equilibrium. For instance, if Φm > Φs, the semiconductor Fermi level is higher than the metal's before contact. The...
794
Biasing of Metal-Semiconductor Junctions
484
Biasing metal-semiconductor junctions involves applying a voltage across the junction. Specifically, the metal is connected to a voltage source, while the semiconductor is grounded. This technique is essential for controlling the direction and magnitude of current flow in electronic devices, including diodes, transistors, and photovoltaic cells.
In Schottky junctions, where the semiconductor is n-type, applying a positive voltage to the metal relative to the semiconductor reduces its Fermi...
In Schottky junctions, where the semiconductor is n-type, applying a positive voltage to the metal relative to the semiconductor reduces its Fermi...
484
Overview of Electron Microscopy
12.7K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
12.7K

