Related Experiment Video
Updated: Dec 23, 2025

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
The Effect of Functional and Intra-Coronary Imaging Techniques on Fluoroscopy Time, Radiation Dose and Contrast
Fernando De la Garza-Salazar1,2, Diana Lorena Lankenau-Vela1,2, Bertha Cadena-Nuñez3
1Universidad de Monterrey, Facultad de Medicina, Especialidades Médicas. Av. Ignacio Morones Prieto 4500, Jesús M. Garza, 66238, San Pedro Garza García, Nuevo Leon, Mexico.
Abstract:
The aim was to analyze the effect of fractional flow reserve (FFR), intravascular ultrasound (IVUS) and optical coherence tomography (OCT) on fluoroscopy time (FT), radiation dose (RD) and contrast volume (CV) in patients undergoing coronary angiography. This case-control study included consecutive patients above the age of 18, who underwent coronary angiography. FT, RD, and CV after each procedure were retrospectively recorded. Multivariate models were used to demonstrate the effect of these complementary studies and other factors, on radiation and contrast exposure. A total of 1047 patients were included, 74.5% were men and the mean (SD) age was 62.4 (12.1) years. Complementary studies performed were: IVUS (n = 237), FFR (n = 56) and OCT (n = 37). FFR and IVUS had a small effect on FT (η = 0.008 B = 2.2, p < 0.001; η = 0.009, B = 2.5, p < 0.001), while OCT had no effect (η = 0.002 B = 2.9, p < 0.183). IVUS, FFR and OCT had no effect on the RD. IVUS did not affect contrast volume (η = 0.002 B = 9.4, p < 0.163) while OCT and FFR had a small effect on CV (η = 0.006 B = 39, p < 0.01; η = 0.008 B = 37, p < 0.003). The number of placed stents had a significant effect on FT (η = 0.192, Β = 4.2, p < 0.001), RD (η = 0.129, Β = 511.8, p < 0.001) and CV (η = 0.177, Β = 40.5, p < 0.001). The use of complementary studies in hemodynamics did not modify the received RD and had a minor effect on FT and the CV used.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies VII: Vascular Imaging
Imaging Studies III: Computed Tomography
Cardiac Catheterization I: Pre-Procedure Overview
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...