Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
[Anesthesia and intensive care ventilators: differences and usability in COVID-19 patients]
Q Notz1, J Herrmann1, J Stumpner1
1Klinik und Poliklinik für Anästhesiologie, Universitätsklinikum Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Deutschland.
Abstract:
The current coronavirus disease 2019 (Covid-19) pandemia is a highly dynamic situation characterized by therapeutic and logistic uncertainties. Depending on the effectiveness of social distancing, a shortage of intensive care respirators must be expected. Concomitantly, many physicians and nursing staff are unaware of the capabilities of alternative types of ventilators, hence being unsure if they can be used in intensive care patients. Intensive care respirators were specifically developed for the use in patients with pathological lung mechanics. Nevertheless, modern anesthesia machines offer similar technical capabilities including a number of different modes. However, conceptual differences must be accounted for, requiring close monitoring and the presence of trained personnel. Modern transport ventilators are mainly for bridging purposes as they can only be used with 100% oxygen in contaminated surroundings. Unconventional methods, such as "ventilator-splitting", which have recently received increasing attention on social media, cannot be recommended. This review intends to provide an overview of the conceptual and technical differences of different types of mechanical ventilators.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation I: Indication and Settings
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...