Related Experiment Video
Updated: Dec 23, 2025

Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
Advanced core-shell EDTA-functionalized magnetite nanoparticles for rapid and efficient magnetic solid phase
Natalia Kobylinska1, Liudmyla Kostenko2, Sergey Khainakov3
1Department of Analytical Chemistry, Taras Shevchenko National University of Kyiv, 64, Volodymyrska Str., Kyiv, 01601, Ukraine. kobilinskaya@univ.kiev.ua.
Abstract:
A method for preconcentration and simultaneous determination of trace heavy metals in water media by core-shell superparamagnetic nanoparticles with the immobilized derivative of ethylenediaminetriacetic acid (referred to as MNPs/SiO2-EDTA) is proposed. The specific layer-by-layer covering of magnetite endowed the new material with essentially increased chemical stability of MNPs including acidic media and improved the affinity toward traces of toxic metal ions. The initial and modified materials were characterized by X-ray powder diffraction, Fourier transform infrared spectroscopy, transmission and scanning electron microscopies, elemental analysis, and vibrating sample magnetometry. The obtained particles were nanodimensional with a 7-12-nm magnetic core and a 4-6-nm silica shell. The MNPs/SiO2-EDTA quantitatively removes heavy metals from contaminated media at pH ≥ 3.5 within 15 min. The adsorption data were successfully fitted to the pseudo-second-order kinetic model. The preconcentration factor was 150 and maximum adsorption capacity was 36.9 mg g-1 for Cu(II), 108.8 mg g-1 for Pb(II), 30.9 mg g-1 for Zn(II), 34.32 mg g-1 for Cr(III), and 59.5 mg g-1 for Cd(II). Due to high stability in the wide range of pH, the magnetic adsorbent can be regenerated at least six times using 0.1 M HNO3. Following adsorption/desorption, determination of metal ions is provided by inductively coupled plasma optical emission spectrometry (ICP-OES) . The linear range of the proposed method is 0.1 - 200 μg L-1. The limits of detection (LOD) are 0.12 μg L-1 for Zn(II); 0.06 μg L-1 for Cd(II); 0.39 for Cu(II); 0.15 μg L-1 for Cr(III); and 0.76 μg L-1 for Pb(II). The method performance was evaluated in the analysis of environmental, tap, and wastewater samples with recoveries in the range of 94.0-104.0%.
More Related Videos
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
10:44Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
Related Concept Videos
Extraction: Advanced Methods
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
EDTA: Auxiliary Complexing Reagents
Ion-Exchange Chromatography
Precipitation and Co-precipitation